Senin, 22 April 2013

DATA SHEET SWITCH LAYER



DATA SHEET SWITCH LAYER



SWITCHBLADE 4000
Layer 3 Modular Switch
AT-SB4004
4 line card capacity
Up to 96 Gb ports
AT-SB4008
8 line card capacity
Up to 192 Gb ports

Designed to meet the most demanding performance requirements of enterprise class networks, the SwitchBlade 4000 Series Layer 3 modular switches are ideally suited to network aggregation and server connectivity. Packaged in four or eight slot modular chassis configurations, the SwitchBlade 4000 Series blends state-of-the-art Layer 3 functionality with industry leading value. Redundancy and resiliency features including hot-swappable Power Supply Units (PSUs), fan trays, line cards and redundant controllers ensure high system availability.The switching architecture delivers wire-speed switching and IP/IPX routing with advanced, flexible policy-based quality of service and rich multicast support. Multiple user interface options provide a set of configuration and control features that facilitate effortless manageability while allowing maximum flexibility and control of the network.

Eliminate network bottlenecks and boost network performance
AT-SB4000 Series offers uncompromised packet switching performance, delivering Layer 2 and
Layer 3 IP/IPX data at wire-speed on all ports regardless of packet size. With a switch capacity
of up to 384 Gbps yielding 286 Mpps of throughput, the AT-SB4000 Series seamlessly
meets the demands of education, government, and enterprise networks.


Secure your company
The AT-SB4000 Series offers many advanced features to ensure company security: Wirespeed
Filtering, MAC control, Port-Intrusion Detection, Access Control Lists, Port Security, Secure Shell (SSH) and Secure Socket Layer (SSL). With 4096 VLANs available, which are
Port, Protocol, Subnet, and MAC Address based, security across VLANs is assured.The security
features (MAC & IP addresses, SYN,ACK bit level) are in the hardware.

Minimize the cost of downtime
The SwitchBlade hot-swappable switch controllers, power supplies, and line cards ensure that this core network device keeps networks alive 24/7. With N+1 power supply redundancy downtime is completely eliminated. Cooling is assured with up to 11 cubic meters / minute of airflow for the four fan AT-SB4004, and up to 19 cubic meters / minute of airflow for the six fan AT-SB4008. Hot-swappable switch controllers provide redundancy and, when two switch controllers are installed, sharing of load for increased performance. Port trunking is provided to assure very reliable high-speed connections. Combining multiple physical connections in a single logical connection provides both greater bandwidth and redundancy . Virtual Router Redundancy Protocol (VRRP) provides automatic router backup in mission-critical environments.This feature enables multiple AT-SB4000 Series switches to share a virtual IP address, used as the default LAN gateway. Should the master fail, the virtual IP address is seamlessly assumed by the other
switches.This results in a down-time of only three seconds. Meanwhile, LAN devices can continue to be configured (for example with DHCP) with a single default gateway address.
Rapid Spanning Tree Protocol (RSTP) prevents loops in Layer 2 networks and also provides rapid system recovery following a failure in the network.

Key Features

Performance

Chassis based aggregation Layer 3 switch
Wide variety of line cards including high density gigabit and 10 gigabit options
Capable of non-blocking wire-speed Layer 2 and 3 switching
Full multiprotocol routing capabilities
Up to 384Gbps of switching capacity yielding 286Mpps of throughput
Up to 4096 VLANs

Quality of Service

Highly programmable QoS with independent latency and bandwidth controls based on Layer 2, 3, and 4 characteristics
Two priority schedulers and eight queues per port

Multicast

PIM DM, PIM SM, DVMRP


Resiliency

High availability provided by two switch controllers and three PSUs
Redundant failover protection when two switch controllers are installed
Sharing of switching load when two switch controllers are installed
Hot swappable to minimize network downtime
STP, RSTP,VRRP

Management

Comprehensive monitoring of environmental and operational conditions, with LED, alarm relay, event logging, and SNMP trap capability
CLI or GUI switch management
Management tools including – SNMP, HTTP Server, HTTP Client,TFTP Client, NTP, SSL, SSH

Quality of Service

The AT-SB4000 Series market leading Quality of Service (QoS) mechanism allows traffic shaping in a highly programmable manner, based on Layer 2 to Layer 4+ packet characteristics.
The resulting 128 different Classes of Traffic enable flexible policy enforcement with
independent latency and 64kbps increment min/max bandwidth guarantees.AT-SB4000
Series units use IEEE 802.1p, DiffServ, Layer 4 filtering and RSVP along with sophisticated
hardware based switching to deliver a rich QoS capability.The AT-SB4000 Series fits into
education and government networks requiring separation of multicast traffic and dual staff and
student networks all running over a single infrastructure. It is also scalable with a large
number of traffic classes with varying requirements as is typical in today’s converged application-based networks.

Multimedia capable multicasting

With multicast protocols such as IGMP, IGMP Snooping, DVMRP, PIM-SM, and PIM-DM, the
AT-SB4000 Series delivers TV cable broadcasting, video conferencing, phoneconferences,
phone, and web-browsing capabilities. Multicasting between VLANs at wire-speed is also offered for streaming server application with clients on different VLANs.

Broadcast storm control

A traffic storm occurs when packets flood the network, creating excessive traffic and degrading network performance.The broadcast storm control (BCSC) feature allows the user to set limits for each VLAN.This is useful to prevent traffic congestion of the network and inefficient usage of the core.
World class software

The AT-SB4000 Series includes AlliedWare software, allowing simple configuration and control without compromising flexibility.The switches have built-in DHCP server;TFTP for image and configuration downloads; Network Time Protocol client and server capabilities; advanced, customizable triggers with an e-mail client allowing unmatched flexibility in monitoring and controlling events; standard CLI and highly intuitive GUI device configuration tools plus full SNMP and MIB support for network management – accessed either in-band or out-of-band via serial console or 10/100Base-T port.The AT-SB4000 Series leads the market with an extensive suite of Layer 2 and Layer 3 features, including static routing, routing protocols (RIP/RIPv2, OSPF),multicast protocols (IGMP, IGMP Snooping,DVMRP, PIM-SM, PIM-DM), IP, IPX, 4096 VLANs, and flexible port trunking with link aggregation.These features are bundled to suit the needs of a standard application or for an advanced architecture.

AlliedWare

A common OS ensures the AT-SB4000 Series Switch will interoperate seamlessly with other Allied Telesis fixed function, modular routers and all Layer 3 to Layer 7 switch families, allowing operational investment protection for training, management and monitoring. A standards-based implementation assures full interoperability with all other major network equipment vendors. The AT-SB4000 Series Switch is shipped "ready to run" with AlliedWare®, a comprehensive software suite that includes all the features, management capabilities and
performance today's networks demand.

AlliedView – EMS

AlliedView-EMS is a Java-based device management solution from Allied Telesis that provides a user-friendly, window-based environment to manage the AT-SB4000 Series Switch, as well as the complete lineup of Allied Telesis managed devices. Whether managing a large network distributed across multiple sites or a small network with only a handful of nodes, AlliedView-EMS provides the tools needed to effectively monitor and proactively manage Allied Telesis's intelligent networking products.

Triggered Events

A trigger sets off an ordered sequence of scripts and commands to be executed when a certain event occurs, providing a powerful mechanism for automating the response to
specific events. Each trigger may reference multiple scripts and any script can be used by any trigger. Using this feature, the AT-SB4000 Series Switch can, for example, send an email alert to the network manager when trouble occurs, or it can automatically shut down an interface to protect against suspected attacks.

Scripts

The scripting facility enables sequences of commands to be stored in a script and replayed at any time, allowing the AT-SB4000 Series Switch to be easily configured or quickly re-configured. This is useful when developing a complex configuration, making the same configuration change to several different Switches, or introducing a configuration change that must occur at a particular time. Scripts can be created on a PC and uploaded to the AT-SB4000 Series Switch, or they can be created using the AT-SB4000 Series Switch's own integrated text editor.They can be activated either from the command line or from a trigger.

Flexibility

With 8 Line Card slots supporting up to 384 ports of 10/100Base-TX (RJ45), 256 ports of 100Base-FX, 192 ports of 10/100/1000Base-T, 192 ports of 1000Base-X or combinations, the
AT-SB4008 provides great porting flexibility. The AT-SB4004 and its 4 Line Card slots support up to 192 ports of 10/100Base-TX (RJ45), 128 ports of 100Base-FX, 96 ports of 10/100/1000Base-T, 96 ports of 1000Base-X or combinations. Cable management at the core of the network is often a major challenge.The AT-SB4008 Switch offers a detachable cable manager to help tame the cabling jungle.


Physical Characteristics

Ethernet Interface Connections

10/100/1000Base-T Shielded RJ-45
100Base-FX MT-RJ multi-mode fiber
1000Base-X SFP multi-mode and single-mode fiber
1000Base-X GBIC multi-mode and single-mode fiber
1000Base-X XFP multi-mode and single-mode fiber
10GBase-R

Power Characteristics

100-240vAC, 50 or 60Hz with a -48vDC version available

Power Supply Units

Each AC power supply is rated at a maximum of 420W with a worst-case efficiency of 65%, which equates to 3A at 230V (or 6A at 110V) on the mains input per power supply.Worst case AC PSU output load regulation is +/- 0.5%. The inrush current under cold start at 230V is 75A and at 110V is 37A. AC PSU MTBF is 84,160 hrs and weighs 3.8kg (8.4 lbs) unpackaged, or 4.3kg (9.5 lbs) packaged. Each DC power supply is rated at a maximum of 420W with a worst-case efficiency of 65%, which equates to 11A at 59Vdc (or 18A at 36Vdc) per power supply on the input side. Worst case DC PSU output load regulation is +/- 0.5%.The inrush current under cold start at 72V is 50A and at 36V is 25A. DC PSU MTBF is 84,160 hrs and weighs 3.6kg (7.9 lbs) unpackaged, or 4.1kg (9.0 lbs) packaged.



Fan Trays

The AT-SB4108 8 slot chassis has a fan tray of six fans with a power consumption of 43W and a weight of 3.7kg (8.2 lbs) unpackaged, or 4.5kg (9.9 lbs) packaged. The AT-SB4104 4 slot chassis has a fan tray of four fans with a power consumption of 15W and a weight of 1.5kg (3.3 lbs) unpackaged, or 2.3kg (5.1 lbs) packaged.

Environmental Specifications

Operating Temp: 0°C to 40°C (32°F to 104°F) Storage Temp: -25°C to 75°C (-13°F to 167°F)
Relative humidity range: 5% to 95% non-condensing Altitude: 10,000ft max

Physical Dimensions

AT-SB4108: Chassis only
15U form factor, 19" rack mount
Height: 666mm (26.3")
Width: 440mm (17.3")
Depth: 343mm (14.2")

AT-SB4104: Chassis only
9U form factor, 19" rack mount
Height: 400mm (15.8")
Width: 440mm (17.3")
Depth: 343mm (14.2")

Weight

AT-SB4108: 19.0kg (41.8lbs) unpackaged, or
29.6kg (65.12 lbs) packaged.
AT-SB4104:13.0kg (27.3lbs) unpackaged, or
22.4kg (49.3 lbs) packaged.

Acoustic Noise

AT-SB4008: 60.0 dB
AT-SB4004: 59.0 dB

Electrical/Mechanical Approvals

EMC Emissions: EN55022 class A, FCC class A, VCCI class 1

Immunity: EN55024: EN61000-4 levels 2 (ESD), 3 (susceptibility), 4 (fast transients), 5 (power
surge), 6 (RF immunity), and 11 (Voltage dips and sags; EN61000-3 levels 2 (Harmonics), and
3 (Flicker) Safety: UL60950, CAN/CSA-C22.2NO. 60950-00, No. 950-M25 AS/NZ3260 EN60950,ACA TS001, IEC60950
Country of Origin
Singapore

Flexibility - SwitchBlade Cards
The AT-SB4008 and AT-SB4004 offer a comprehensive set of line cards for complex networks.

Key Features

Hot swappable
Can be used in both AT-SB4108 and AT-SB4104 chassis
LEDs identify port activity
ASIC switching

Interface options to cover a variety of network needs.

A diverse range of interface options – including copper and fibre, short and long haul, (SFPs, and
XFPs) - delivers network managers the flexibility and freedom needed to tame today's fast-paced
yet price-conscious network environments. Combining speed and reliability for the network core.
Capable of wire-speed non-blocking switching, and hot swappable to minimize downtime, SwitchBlade line cards are designed to perform when performance is critical.

AT-SB4211A Switch Controller

Two Application-Specific Integrated Circuit (ASIC) switch chips per switch controller
104 k-entry forwarding address database
128 MByte RAMBUS packet buffer

Processing Core
500 MHz IBM 750L PowerPC Processor
1 Mbyte of external L2 cache
256 MBytes Synchronous SDRAM
64 bit memory width
32 MBytes flash memory
512 kBytes Non-volatile Storage SRAM (NVRAM)
Battery backed real time clock (RTC)

Asynchronous Serial Configuration Port
Up to 115 kbps
Standard DB9 female RS-232 connector
Hardware or software flow control 10/100Base-TX Management Port
10/100Base-TX MDI port with RJ-45 connector
LEDs indicate link activity, full/half-duplex, and collisions

Environmental and Fault Monitoring
Fault LEDs indicate:
Switch controller or software malfunction
PSU or PSU fan malfunction
Fan tray fan failure
Fan tray removal
Excess temperature of CPU
SDRAM (DIMM) not recognized
SDRAM (DIMM) not compatible

Alarm relays can indicate:
PSU status
Fan tray removal
Fan tray fan status
Excess temperature of CPU
Exceeding user settable temperature at CPU
Port status change
Manager login
Event logs and messages can also be generated for a range of fault and operational conditions

Power Consumption
60 W
MTBF
188,560 hrs
LEDs
LEDs for system status, fault indication, and management port status
Weight
2.5 kg (5.5 lbs) unpackaged, or 3.3 kg (7.3 lbs) packaged

AT-SB4215 Bandwidth Expander
Designed for use with the AT-SB4104 chassis
An economical alternative to a second switch controller
Unlocks the chassis's full bandwidth potential, without the need for a second switch controller
Does not perform switching functions or switch controller redundancy
Ideal for cost conscious networks where maximum bandwidth is a higher priority than switch controller redundancy

Power Consumption
0 W
Compatibility
Use in slot B of the AT-SB4104 chassis only
Weight
2.3 kg (5.1 lbs) unpackaged, or 3.1 kg (6.7 lbs) packaged

SwitchBlade Line Cards
All line cards have:
ASIC switch chips operating in Layer 3 mode
40 k-entry forwarding address database
Support for protocol-based VLANS and MAC address learning
64 MByte RAMBUS packet buffer per switch chip
33MHz 64bit PCI control bus

AT-SB4311 48-Port (RJ-45) Fast
Ethernet Line Card
48 auto-negotiating 10/100Base-TX ports
Auto MDI/MDI-X negotiation as default (MDI-X if negotiation is disabled)
RJ-45 connectors

LEDs
Single (switchable) dual-mode LED per port Indicates full/half duplex, collisions, and link activity and speed (10/100)

Power Consumption
30W

MTBF
322,560 hrs

Weight
2.3 kg (5.1 lbs) unpackaged, or 3.1 kg (6.7 lbs) packaged

AT-SB4352 32-Port (MT-RJ) 100Mb Line Card
32 100Base-FX ports
MT-RJ connectors

LEDs
Two per port
Indicate full/half duplex, collisions, and link activity

Power Consumption
53W

MTBF
83,590 hrs

Weight
2.5 kg (5.5 lbs) unpackaged, or 3.3 kg (7.2 lbs) packaged

AT-SB4411A 8-Port (RJ-45) Gigabit Ethernet Line Card
8 auto-negotiating 10Base-T/ 100Base-TX/1000Base-T ports
Auto MDI/MDI-X negotiation as default (MDIX if negotiation is disabled)
RJ-45 connectors

LEDs
Two per port
Indicate full/half duplex, collisions, and link activity and bps speed (10/100/1000)

Power Consumption
30W

MTBF
456,137 hrs

Weight
2.2 kg (4.9 lbs) or 3.0 kg (6.5 lbs) packaged

AT-SB4412 24-Port (RJ-45) Gigabit
Ethernet Line Card
24 auto-negotiating 10/100Base-TX/ 1000Base-T ports
Auto MDI/MDI-X negotiation as default (MDI-X if negotiation is disabled)
RJ-45 connectors
LEDs
Two per port
Indicate full/half duplex, collisions, and link activity and bps speed (10/100/1000)

Power Consumption
82W

MTBF
357,000 hrs

Weight
2.4 kg (5.3 lbs) unpackaged, or 3.2 (7.0 lbs) packaged

AT-SB4441A 8-GBIC Line Card
8 1000Base-X ports
Compatible with copper (1000Base-T) and fibre (1000Base-SX and 1000Base-LX) GBICs
Compatible with ATI GBICs (see Ordering information - Gigabit Interface Converter (GBIC) Modules)

LEDs
Two per port
Indicate link activity, half duplex, and GBIC status

Power Consumption
50W

MTBF
310,500 hrs


Weight
2.3 kg (5.1 lbs) or 3.1 kg (6.7 lbs) packaged

AT-SB4442 24-Port SFP Gigabit
Line Card
24 1000Base-X
SFP (small form pluggable) connectors

LEDs
Two per port
Indicate link activity, half duplex, and SFP status

Power Consumption
85W

MTBF
300,000 hours
Weight
2.4 kg (5.3 lbs) unpackaged, or 3.2 (7.0 lbs) packaged

AT-SB4541A 10 Gigabit Ethernet
Line Card
1 x 10GBase-R
Compatible with a hot-swappable XFP module

LEDs
Two
Indicate link activity and XFP status
Power Consumption
58W

MTBF
330,000 hrs

Weight
2.2 kg (4.9 lbs) unpackaged, or 3.0 kg (6.5 lbs) packaged

Power Outputs for Optical Ports

Card
Wave Length
Fibre Type
Transmitter
dBm Min
Receiver Sensitivity Max dBm
(of same card)
dBm loss allowed
Max. 1
Minimum distance using IEEE 802.3 fibre attenuation
(Km)2 3
Received Power
Max. dBm avg.4
AT-SB4352
32 port (MT-RJ)
1310nm
50.0um
-20
-31
6
4.0
-14
AT-SB4352
32 port (MT-RJ)
1310nm
62.5um
-23.5
-31
2.5
1.7
-14

Maximum fibre attenuation per km from IEEE 802.3 Table 38-12

Description
62.5um MMF
50um MMF
10um SMF Unit
Nominal fibre specification wavelength (nM)

850

1300

850

1300

1310
Fibre cable attenuation (max) (dB/km)5

3.75

1.5

3.5

1.5

0.5



DATA SHEET SWITCH LAYER 2 DAN 3



Layer 2 Switch 


Menjembatani teknologi telah ada sejak tahun 1980-an (dan bahkan mungkin sebelumnya). Bridging melibatkan segmentasi jaringan area lokal (LAN) pada Layer 2 tingkat. Sebuah jembatan multiport biasanya belajar tentang Media Access Control (MAC) alamat di setiap pelabuhan dan transparan melewati frame MAC ditakdirkan untuk orang-port. Jembatan ini juga memastikan bahwa frame ditakdirkan untuk alamat MAC yang terletak pada port yang sama sebagai stasiun yang berasal tidak diteruskan ke port lain. Untuk kepentingan diskusi ini, kami hanya mempertimbangkan Ethernet LAN. 
Layer 2 switch secara efektif memberikan fungsi yang sama. Mereka mirip dengan multiport jembatan di bahwa mereka belajar dan bingkai maju pada port masing-masing. Perbedaan utama adalah keterlibatan perangkat keras yang memastikan bahwa beberapa switching path di dalam saklar dapat diaktifkan pada waktu yang sama. Sebagai contoh, perhatikan Gambar 1, yang merinci suatu saklar empat-port dengan stasiun A pada port 1, B di port 2, C pada port 3 dan D pada 4 port. Asumsikan bahwa A keinginan untuk berkomunikasi dengan B, dan C keinginan untuk berkomunikasi dengan D. Di jembatan CPU tunggal, forwarding ini biasanya akan dilakukan dalam perangkat lunak, di mana CPU akan mengambil frame dari masing-masing pelabuhan secara berurutan dan ke depan mereka sesuai output port.
Proses ini sangat efisien dalam skenario seperti yang ditunjukkan sebelumnya, di mana lalu lintas antara A dan B tidak ada hubungannya dengan lalu lintas antara C dan D.  Gambar 1: Layer 2 saklar eksternal dengan Router untuk lalu lintas Inter-VLAN dan menghubungkan ke Internet (Klik pada gambar untuk memperbesar.) Masukkan hardware berbasis Layer 2 switching. Layer 2 switch dengan dukungan hardware mereka bisa maju bingkai secara paralel sehingga A dan B dan C dan D dapat melakukan percakapan simultan. Sejajar-isme memiliki banyak keuntungan. Asumsikan bahwa A dan B adalah NetBIOS stasiun, sedangkan C dan D adalah Internet Protocol (IP) stasiun. Mungkin tidak ada rea-anak untuk komunikasi antara A dan C dan A dan D. Layer 2 switching memungkinkan ini hidup berdampingan tanpa mengorbankan efisiensi. 


Virtual LAN 

Namun dalam kenyataannya, LAN jarang sangat bersih. Asumsikan situasi dimana A, B, C, dan D adalah semua stasiun IP. A dan B termasuk ke dalam subnet IP yang sama, sedangkan C dan D milik subnet yang berbeda. Layer 2 switching baik-baik saja, selama hanya A dan B atau C dan D berkomunikasi. Jika A dan C, yang pada dua subnet IP yang berbeda, perlu berkomunikasi, Layer 2 switching tidak memadai? Komunikasi yang membutuhkan router IP. Sebuah konsekuensi dari ini adalah bahwa A dan B dan C dan D milik domain siaran yang berbeda yaitu, A dan B tidak boleh?? Lihat? siaran lapisan MAC dari C dan D, dan sebaliknya. Namun, suatu Layer 2 saklar tidak dapat membedakan antara siaran menjembatani melibatkan teknologi broadcast forwarding ke semua port lain,? Dan tidak dapat mengetahui bahwa suatu siaran terbatas pada subnet IP yang sama. 
Virtual LAN (VLAN) berlaku dalam situasi ini. Singkatnya, VLAN adalah Layer 2 Layer 2 domain penyiaran. MAC siaran terbatas pada VLAN yang dikonfigurasi ke stasiun. Bagaimana Layer 2 saklar membuat perbedaan ini? Dengan konfigurasi. VLAN melibatkan konfigurasi port atau alamat MAC. Port-based VLAN menunjukkan bahwa semua frame yang berasal dari pelabuhan milik VLAN yang sama, sementara alamat MAC VLAN berbasis menggunakan alamat MAC untuk menentukan keanggotaan VLAN. Dalam Gambar 1, port 1 dan 2 milik VLAN yang sama, sedangkan 3 dan 4 milik port ke VLAN yang berbeda. Perlu diketahui bahwa ada hubungan implisit antara VLAN dan IP subnet Namun,? Konfigurasi dari Layer 2 VLAN tidak melibatkan menentukan parameter Layer 3. 
Kami menunjukkan sebelumnya bahwa stasiun pada dua VLAN yang berbeda dapat com-municate hanya melalui router. Router biasanya terhubung ke salah satu port switch (Gambar 1). router ini kadang-kadang disebut sebagai router satu-bersenjata karena ke depan menerima dan lalu lintas ke port yang sama. Pada kenyataannya, tentu saja, router tersebut terhubung ke switch lain atau untuk jaringan yang luas (WAN). Beberapa Layer 2 switch menyediakan fungsi Layer 3 routing dalam kotak yang sama untuk menghindari router exter-nal dan bebas lain port switch. Skenario ini mengingatkan pada router Multiprotocol besar awal 90-an,? yang menawarkan fungsi routing dan bridging. 
Sebuah klasifikasi yang populer Layer 2 switch adalah? Dipotong-melalui? versus toko-dan-maju.?? Potong-melalui switch membuat keputusan forwarding sebagai frame yang diterima dengan hanya melihat header dari frame. Store-dan-forward switch menerima seluruh Layer 2 frame sebelum membuat keputusan forwarding. switch Hybrid beradaptasi yang mengadaptasi dari cut-sampai toko-dan-maju berdasarkan tingkat kesalahan dalam frame MAC yang sangat populer. 


Karakteristik 

Layer 2 switch sendiri bertindak sebagai akhir node IP untuk Wikipedia Network Management Protocol (SNMP) manajemen, Telnet, dan manajemen berbasis web. fungsi manajemen tersebut melibatkan kehadiran IP stack pada router bersama dengan User Datagram Protocol (UDP), Transmission Control Protocol (TCP), Telnet, dan fungsi SNMP. Akan aktif sendiri memiliki alamat MAC sehingga mereka dapat diatasi sebagai node Layer 2 akhir sementara juga menyediakan fungsi switch transparan. Layer 2 switching tidak, pada umumnya, melibatkan mengubah bingkai MAC. Namun, ada beberapa situasi ketika switch mengubah bingkai MAC. IEEE 802.1Q Komite ini bekerja pada standar VLAN yang melibatkan? Penandaan? bingkai MAC dengan VLAN itu milik; proses penandaan ini melibatkan perubahan frame MAC. Menjembatani teknologi juga melibatkan Protokol Spanning-Tree. Hal ini diperlukan dalam jaringan multibridge untuk menghindari loop. 
Prinsip yang sama juga berlaku terhadap Layer 2 switch, dan yang paling komersial Layer 2 switch mendukung Protokol Spanning-Tree. Pembahasan sebelumnya memberikan garis besar Layer 2 switching func-tions. Layer 2 switching adalah berdasarkan MAC frame, tidak melibatkan mengubah bingkai MAC, secara umum, dan menyediakan switching transparan dalam nominal-alel dengan bingkai MAC. Karena switch beroperasi pada Layer 2, mereka adalah protokol independen. Namun, Layer 2 switching skala tidak baik karena siaran. Meskipun VLAN mengatasi masalah ini sampai batas tertentu, pasti ada kebutuhan untuk mesin pada VLAN yang berbeda untuk berkomunikasi. Salah satu contoh adalah situasi di mana sebuah orga-nization memiliki beberapa server intranet pada subnet yang terpisah (dan karenanya VLAN), menyebabkan banyak lalu lintas intersubnet. Dalam kasus tersebut, penggunaan router yang tidak dapat dihindari; Layer 3 switch masukkan pada saat ini. 

Layer 3 Switch 

Layer 3 switching adalah istilah yang relatif baru, yang telah? Diperpanjang? oleh berbagai vendor untuk menggambarkan produk mereka. Misalnya, satu sekolah menggunakan istilah ini untuk menggambarkan IP routing cepat melalui perangkat keras, sedangkan sekolah lain menggunakannya untuk menggambarkan Multi Protokol Lebih dari ATM (MPOA). Untuk tujuan diskusi ini, Layer 3 switch superfast kekalahan-ers yang Layer 3 forwarding di hardware. Pada artikel ini, kita terutama akan membahas Layer 3 switching dalam konteks IP routing cepat, dengan diskusi singkat dari daerah lain dari aplikasi. 

Evolusi 

Pertimbangkan konteks Layer 2 switching ditunjukkan pada Gambar 1. Layer 2 switch beroperasi dengan baik ketika ada lalu lintas yang sangat sedikit antara VLAN. Seperti lalu lintas VLAN akan memerlukan router baik?? Tergantung off? salah satu pelabuhan sebagai router satu-bersenjata atau hadir dalam internal switch. Untuk menambah fungsi Layer 2, kita membutuhkan sebuah router? Yang mengakibatkan hilangnya kinerja karena router biasanya lebih lambat daripada switch. Skenario ini mengarah ke pertanyaan: Mengapa tidak menerapkan sebuah router di dalam saklar itu sendiri, seperti dijelaskan pada bagian sebelumnya, dan melakukan forwarding di hardware? Meskipun konfigurasi ini adalah mungkin, memiliki satu batasan: Layer 2 switch perlu beroperasi hanya pada frame Ethernet MAC. Skenario ini pada gilirannya menyebabkan algoritma forwarding yang jelas yang dapat diimplementasikan dalam perangkat keras. Algoritma ini tidak dapat diperpanjang dengan mudah untuk layer 3 protokol karena ada beberapa Layer 3 routable protokol seperti IP, IPX, AppleTalk, dan seterusnya, dan kedua, keputusan forwarding di protokol seperti biasanya lebih rumit daripada Layer 2 keputusan forwarding. 
Apa kompromi rekayasa? Karena IP adalah yang paling umum di antara semua protokol Layer 3 hari ini, sebagian besar switch Layer 3 hari ini melakukan IP switching di tingkat hardware dan meneruskan protokol lain di layer 2 (yaitu, jembatan mereka). Isu kedua yang rumit 3 keputusan Layer forwarding terbaik diilustrasikan dengan pengolahan opsi IP, yang biasanya menyebabkan panjang header IP bervariasi, rumit membangun mesin forwarding hardware. Namun, sejumlah besar paket IP tidak termasuk opsi IP? Begitu, mungkin memerlukan banyak usaha keras untuk merancang pengolahan ini ke silikon. kompromi adalah bahwa keputusan forwarding paling umum (jalan cepat) dirancang menjadi silikon, sedangkan yang lainnya biasanya ditangani oleh CPU pada Layer 3 switch. 
Sebagai rangkuman, Layer 3 switch router dengan cepat forwarding dilakukan melalui perangkat keras. IP forwarding biasanya melibatkan pencarian rute, decrementing Waktu Untuk Live (TTL) menghitung dan menghitung ulang checksum, dan meneruskan frame dengan header MAC sesuai dengan port output yang benar. Lookup dapat dilakukan di perangkat keras, demikian juga decrementing dari TTL dan perhitungan kembali dari checksum. Router menjalankan routing protokol seperti Open Shortest Path First (OSPF) atau Routing Informasi Protocol (RIP) untuk berkomunikasi dengan lainnya Layer 3 switch atau router dan membangun tabel routing mereka. Routing tabel ini dicari untuk menentukan rute untuk paket masuk. 

2/Layer Gabungan Layer 3 Switches 

Kami telah secara implisit mengasumsikan bahwa Layer 3 switch Layer 2 juga menyediakan fungsionalitas switching, tetapi asumsi ini tidak selalu benar terus. Layer 3 switch dapat bertindak seperti router tradisional menggantung di beberapa Layer 2 switch dan menyediakan konektivitas antar-VLAN. Dalam kasus tersebut, tidak ada Layer 2 fungsi yang diperlukan dalam switch. Konsep ini dapat diilustrasikan dengan memperluas topologi dalam Gambar 1? mempertimbangkan menempatkan Layer murni 3 beralih antara Layer 2 Switch dan router. Layer 3 Switch akan off-load router dari pengolahan antar-VLAN. Gambar 2: 
Beralih Layer2/Layer3 Gabungan menghubungkan langsung ke Internet  (Klik pada gambar untuk memperbesar.)  Gambar 2 mengilustrasikan Layer 3 switching 2/Layer gabungan fungsi-ality. Layer 3 switch gabungan 2/Layer menggantikan router tradisional juga. A dan B milik subnet IP 1, sedangkan C dan D milik subnet IP 2. Karena pertimbangan switch adalah switch Layer 2 juga, itu switch lalu lintas antara A dan B pada Layer 2. Sekarang perhatikan situ-asi jika A ingin berkomunikasi dengan C. mengirimkan paket IP dialamatkan ke alamat MAC dari switch Layer 3, tetapi dengan tujuan alamat IP sama dengan C? Alamat IP. Strip Layer 3 beralih dari MAC header frame dan switch ke C setelah melakukan pencarian itu, decrementing yang TTL, menghitung ulang checksum dan memasukkan C? Alamat MAC di bidang alamat tujuan MAC. Semua langkah-langkah yang dilakukan pada perangkat keras dengan kecepatan yang sangat tinggi. 
Sekarang bagaimana mengaktifkan tahu bahwa C? S alamat tujuan IP Port 3? Ketika melakukan pembelajaran pada Layer 2, itu hanya tahu C? Alamat MAC. Ada beberapa cara untuk memecahkan masalah ini. switch ini bisa melakukan Address Resolution Protocol (ARP) lookup pada semua subnet IP 2 port C? s alamat MAC dan menentukan C IP-to-MAC pemetaan dan pelabuhan yang terletak C?. Metode lainnya adalah untuk saklar untuk menentukan C IP-to-MAC pemetaan? Oleh mengintip ke dalam header IP pada penerimaan sebuah frame MAC. 

Karakteristik

Konfigurasi dari 3 switch Layer merupakan masalah penting. Ketika switch Layer 3 juga melakukan Layer 2 switching, mereka mempelajari alamat MAC pada port hanya konfigurasi yang diperlukan adalah konfigurasi VLAN?. Untuk Layer 3 switching, itu switch dapat dikonfigurasi dengan port sesuai dengan masing-masing subnet atau alamat IP dapat melakukan belajar. Proses ini melibatkan mengintip ke dalam header IP dari frame MAC dan menentukan subnet pada port dari sumber alamat IP. Ketika tindakan Layer 3 switch seperti router satu-bersenjata untuk switch Layer 2, port yang sama dapat terdiri dari beberapa IP subnet. 
Manajemen Layer 3 switch biasanya dilakukan melalui SNMP. Layer 3 switch juga memiliki alamat MAC untuk pelabuhan mereka? Konfigurasi ini dapat menjadi salah satu per port, atau semua port dapat menggunakan alamat MAC yang sama. Layer 3 switch biasanya menggunakan alamat MAC untuk SNMP, Telnet, dan komunikasi Web manajemen. 
Secara konseptual, Forum ATM? S LAN Emulation (LANE) specificat-ion lebih dekat dengan Layer 2 switching model, sedangkan MPOA lebih dekat dengan Layer 3 switching model. Sejumlah Layer 2 switch dilengkapi dengan antarmuka ATM dan menyediakan fungsi klien LANE pada antarmuka ATM. Skenario ini memungkinkan bridging dari frame MAC di seluruh jaringan ATM dari beralih ke switch. MPOA ini lebih dekat dengan gabungan 3 switching Layer2/Layer, meskipun MPOA klien tidak memiliki protokol routing berjalan di atasnya. (Routing adalah kiri ke server MPOA bawah model Router Virtual.)  Apakah Layer 3 switch sepenuhnya menghilangkan kebutuhan untuk router tradisional? Tidak, router masih diperlukan, terutama di mana koneksi ke area yang luas dibutuhkan. Layer 3 switch masih dapat terhubung ke router tersebut untuk belajar meja mereka dan paket rute untuk mereka ketika paket tersebut harus dikirim melalui WAN. Akan aktif akan sangat efektif pada workgroup dan tulang punggung di dalam perusahaan, tetapi kemungkinan besar tidak akan mengganti router di tepi WAN (baca internet dalam banyak kasus). Router melakukan berbagai fungsi lainnya seperti penyaringan dengan daftar akses, antar Autonomous System (AS) dengan protokol routing seperti Border Gateway Protocol (BGP), dan seterusnya. Beberapa Layer 3 switch sepenuhnya dapat menggantikan kebutuhan penerus jika mereka dapat memberikan semua fungsi ini

Tidak ada komentar:

Posting Komentar